From 1376130d795b214a99c8fdc11944a1555dcf7363 Mon Sep 17 00:00:00 2001 From: Ingo <71161062+iseeberg79@users.noreply.github.com> Date: Sun, 18 Jan 2026 13:10:59 +0100 Subject: [PATCH 1/2] Revert "KOSTAL Plenticore (Gen 2): enable charging during hold mode (#26169)" This reverts commit ddcb47b138f7efc9a1749edc84a6f8de30be2ef5. --- templates/definition/meter/kostal-plenticore-gen2.yaml | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/templates/definition/meter/kostal-plenticore-gen2.yaml b/templates/definition/meter/kostal-plenticore-gen2.yaml index 841d7fe7f4..b2f9ea0e4d 100644 --- a/templates/definition/meter/kostal-plenticore-gen2.yaml +++ b/templates/definition/meter/kostal-plenticore-gen2.yaml @@ -97,7 +97,7 @@ render: | source: modbus {{- include "modbus" . | indent 10 }} register: - address: 1040 # Battery max. discharge power limit, absolute [W] + address: 1034 # Battery charge power (DC) setpoint, absolute [W] type: writemultiple encoding: {{ if (eq .endianness "big") }}float32{{ else }}float32s{{ end }} - case: 3 # charge From 84cb5c34a8491f2ee18f8e5ff297cbdf97c21f99 Mon Sep 17 00:00:00 2001 From: Ingo <71161062+iseeberg79@users.noreply.github.com> Date: Sun, 18 Jan 2026 14:43:26 +0100 Subject: [PATCH 2/2] update description --- .../meter/kostal-plenticore-gen2.yaml | 24 ++++++++++++++----- .../definition/meter/kostal-plenticore.yaml | 12 +++++++--- 2 files changed, 27 insertions(+), 9 deletions(-) diff --git a/templates/definition/meter/kostal-plenticore-gen2.yaml b/templates/definition/meter/kostal-plenticore-gen2.yaml index c4bca356be..349695657d 100644 --- a/templates/definition/meter/kostal-plenticore-gen2.yaml +++ b/templates/definition/meter/kostal-plenticore-gen2.yaml @@ -9,13 +9,25 @@ covers: ["kostal-plenticore-hw0200"] requirements: description: de: | - Nur ein System kann und darf auf den Wechselrichter zugreifen! Für die aktive Batteriesteuerung muss die Funktion externe Batteriesteuerung über Modbus mit dem Handwerkerzugang aktiviert sein. **_Ist grundsätzlich anwendbar für verschiedene Wechselrichter Generationen (G1/G2/G3)._** - **Das Netzladen der Batterie steht mit dieser Vorlage zur Verfügung, ist aktuell jedoch inkompatibel mit wenigen älteren Wechselrichtern - _sorgfältig testen_!** - _siehe auch https://github.com/evcc-io/evcc/wiki/Kostal-Plenticore_ + Nur ein System kann und darf auf den Wechselrichter zugreifen! Für die aktive Batteriesteuerung muss die Funktion externe Batteriesteuerung über Modbus mit dem Handwerkerzugang aktiviert sein. + + **Einschränkung:** Im gesperrten Zustand ist keine Ladung der Hausbatterie möglich. + + **Wechselrichter-Generationen:** Grundsätzlich anwendbar für G1/G2/G3 + + **Netzladen:** Funktion verfügbar, jedoch mit wenigen älteren Wechselrichtern inkompatibel - _sorgfältig testen_! + + Weitere Informationen: [github.com/evcc-io/evcc/wiki/Kostal-Plenticore](https://github.com/evcc-io/evcc/wiki/Kostal-Plenticore) en: | - Only a single system may access the inverter! For active battery control, the feature external battery control via modbus must be activated using installer access. **_Can basically be used for various inverter generations (G1/G2/G3)._** - **The function for grid charging the battery is available using this template, but is currently incompatible with some older inverters - _test carefully_!** - _see also https://github.com/evcc-io/evcc/wiki/Kostal-Plenticore_ + Only a single system may access the inverter! For active battery control, the feature external battery control via Modbus must be activated using installer access. + + **Limitation:** Battery charging is not possible when locked. + + **Inverter generations:** Can basically be used for G1/G2/G3 + + **Grid charging:** Function available, but currently incompatible with some older inverters - _test carefully_! + + Further information: [github.com/evcc-io/evcc/wiki/Kostal-Plenticore](https://github.com/evcc-io/evcc/wiki/Kostal-Plenticore) params: - name: usage choice: ["pv", "battery"] diff --git a/templates/definition/meter/kostal-plenticore.yaml b/templates/definition/meter/kostal-plenticore.yaml index 7fbe96fef7..21c6b259f5 100644 --- a/templates/definition/meter/kostal-plenticore.yaml +++ b/templates/definition/meter/kostal-plenticore.yaml @@ -7,11 +7,17 @@ capabilities: ["battery-control"] requirements: description: de: | - Nur ein System kann und darf auf den Wechselrichter zugreifen! Für die aktive Batteriesteuerung muss die Funktion externe Batteriesteuerung über Modbus mit dem Handwerkerzugang aktiviert sein. - **Das Netzladen der Batterie steht nicht zur Verfügung!** _siehe auch https://github.com/evcc-io/evcc/wiki/Kostal-Plenticore_ + Nur ein System kann und darf auf den Wechselrichter zugreifen! Für die aktive Batteriesteuerung muss die Funktion externe Batteriesteuerung über Modbus mit dem Handwerkerzugang aktiviert sein. + + **Einschränkung:** Das Netzladen der Batterie steht nicht zur Verfügung! + + Weitere Informationen: [github.com/evcc-io/evcc/wiki/Kostal-Plenticore](https://github.com/evcc-io/evcc/wiki/Kostal-Plenticore) en: | Only a single system may access the inverter! For active battery control the function external battery control via Modbus must be activated using installer access. - **Grid charging is not available!** _see also https://github.com/evcc-io/evcc/wiki/Kostal-Plenticore_ + + **Limitation:** Grid charging is not available! + + Further information: [github.com/evcc-io/evcc/wiki/Kostal-Plenticore](https://github.com/evcc-io/evcc/wiki/Kostal-Plenticore) params: - name: usage choice: ["pv", "battery"]