Describe the bug
When trying to get supported features, the Non-Bayer feature ‘NoiseReduction’ shows that it is available, even when I’m selecting Bayer-8 in Image format. Also it is returning bounds of -inf and inf, whereas the other feature in its Node Group , ‘SharpnessEnhancement’ returns 0.0
To Reproduce
Connect a basler camera and choose the Bayer-8 color format.
Expected behavior
The feature should be shown as unavailable
Camera description:
- Manufacturer: Basler
- Model: Basler-267601797A7F-24738431
- Interface: USB3
Platform description:
- Aravis version
- OS: Ubuntu 22.04
- Hardware: x86_64
bsler.xml